Product Overview
The 70KW Cummins Diesel Generator is a premium power solution, featuring the 4BTA3.9-G13 Cummins diesel engine combined with the Stamford UCI224F1 alternator. Designed for optimal fuel efficiency and extended lifespan, this generator delivers reliable power with a standby output of 70KW (prime power: 64KW) at 50Hz frequency. Its high power-to-weight ratio ensures superior performance while maintaining a compact and lightweight structure for easier transportation and installation.
Key Features & Benefits
✔ Reliable and Durable Performance – Built to withstand demanding conditions with high-strength components and a heavy-duty workload capacity.
✔ Efficient Fuel Consumption – Designed for maximum fuel economy, reducing long-term operational costs.
✔ Advanced Engineering – Integrated cylinder block and head design minimizes leaks and reduces component count by 40% compared to similar engines, ensuring lower failure rates.
✔ Precision Air and Fuel Management – Equipped with a Holset turbocharger with an integrated wastegate, offering quick response and powerful performance.
✔ Enhanced Fuel Filtration System – A three-stage fuel filtration system ensures even particle distribution, protecting key fuel system components and extending engine life.
✔ Superior Voltage and Frequency Stability – Provides stable voltage and frequency regulation, reducing power fluctuations and ensuring reliable operation.
✔ Compact and Easy Installation – A well-optimized power-to-weight ratio makes installation and transport hassle-free.
✔ Industry-Standard Compliance – Meets ISO8528-2005 & GB/T2820-2009 standards, ensuring quality and reliability.
✔ Comprehensive Warranty & Support – Includes a 1-year or 1,000 operating hours warranty covering the engine, alternator, and control system, backed by a nationwide 24/7 technical support network.
Technical Specifications
Generator Set Specifications
- Model: XN-70CDG
- Standby Power: 70KW
- Prime Power: 64KW
- Speed: 1500 RPM
- Fuel Consumption: 211 g/kW.h
- Frequency: 50Hz
- Voltage Stability: ±1%
- Voltage Waveform Distortion: ≤8%
- Transient Voltage Regulation: ≤ -15% / +20%
- Steady-State Frequency Regulation: ≤5%
- Transient Frequency Regulation: ≤ -10% / +12%
- Voltage Recovery Time: ≤3 seconds
- Frequency Recovery Time: ≤3 seconds
- Overall Dimensions (L × W × H): 2250 × 800 × 1325 mm
- Weight: 1160 kg
Engine Specifications
- Brand: Cummins
- Manufacturer: Dongfeng Cummins Engine Co., Ltd. (DCEC)
- Model: 4BTA3.9-G13
- Standby Power: 97KW
- Rated Power: 87KW
- Cylinders & Configuration: 4 cylinders, inline
- Displacement: 3.9L
- Bore & Stroke: 102mm × 120mm
- Compression Ratio: 17.5:1
- Oil Capacity: 10.9L
- Cooling System: Closed-loop water cooling
- Injection System: PB inline pump
- Governor Type: Electronic
- Starting System: DC24V Electric Start
- Turbocharged & Intercooled: Yes
Alternator Specifications
- Brand: Stamford
- Manufacturer: Cummins Generator Technologies (China) Co., Ltd.
- Model: UCI224F1
- Capacity: 80 KVA
- Voltage: 400V/230V
- Excitation System: Self-excited, AVR-controlled
- Winding Pitch: 2/3 pitch
- Insulation Class: H-class
- Power Factor: 0.8 (lagging)
- Connection Type: Y (star) connection
- Total Harmonic Factor (THF): <2%
- Telephone Influence Factor (TIF): <50
- Protection Class: IP23
- Compliance Standards: GB755, BS5000 (Part 3), VDE0530, NEMA MG1-22, IEC-34, GSA C22-100, AS1359
Environmental Conditions
- Altitude: ≤1000m
- Fuel Type: 0# Light Diesel
- Atmospheric Pressure: ≥89.9 kPa
- Lubrication Oil: CF Grade / 15W-40
- Intake Air Temperature: ≤40°C
- Water pH Value: 6.5–8
- Relative Humidity: ≤60%
- Mildew Resistance Level: GB/T2423.16 Level 2
- Seismic Resistance: Horizontal acceleration 0.2g, vertical acceleration 0.1g
Standard Configuration
🔹 Engine Components: Diesel engine, fuel filter, air filter, oil filter, charging alternator, starter motor.
🔹 Generator Components: Stamford alternator, air circuit breaker.
🔹 Control System: LCD digital controller, electronic governor.
🔹 Additional Accessories: Silencer, battery, battery cables, engine oil, anti-vibration mounts.
Certifications & Compliance
✅ Military Standard: GJB 5785-2006
✅ National Standard: GB/T 2820-2002
✅ Telecom Standard: YD/T 502-2007
✅ Industry Standard: JB/T 10303-2001
✅ Environmental Compliance: Noise & emissions rated at Grade A
✅ Quality Certification: YD/T502-2007 (TÜV Certified)
Product configuration and details



Successful Project

Logistics Packaging

Get Your 60KW Cummins Diesel Generator Today!
Whether you need a dependable backup power source for your business or a primary power solution for industrial applications, the 70KW Cummins Diesel Generator is a top-tier choice. Contact us today for pricing, availability, and customization options!
📧 Email: [ gmail@xn-gen.com]
📞 Phone: [+86 15216161715]
🌐 Website: [xn-gen.com]
Generator Maintenance and Servicing
At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).
Routine Maintenance
Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:
- Inspect all rotating components and tighten any loose bolts.
- Check the oil level in the crankcase and add oil if necessary.
- Monitor fuel levels in the tank.
- Inspect the coolant level in the radiator.
- Examine fuel and water pipelines for any leaks or loose connections.
- Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
- Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.
Maintenance Plan for Standby Generators
(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)
Professional Maintenance (Every Six Months or Annually)
In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:
- Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
- Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
- Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
- Drain and replace coolant, ensuring proper radiator function.
- Check and replenish the battery electrolyte or distilled water as needed.
- After completing the maintenance, conduct a final inspection and clean the generator set.
- Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.
Maintenance Plan for Continuous Operation Generators
(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)
Level 1 Maintenance (Every 50-80 Hours)
This includes all routine maintenance tasks plus:
- Clean the air filter and replace it if necessary.
- Replace the diesel filter, air filter, and water filter.
- Inspect the tension of the drive belt and adjust if needed.
- Lubricate all grease fittings and moving components.
- Replace coolant to maintain effective cooling performance.
Level 2 Maintenance (Every 250-300 Hours)
Includes Level 1 maintenance tasks, with additional checks:
- Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
- Examine the main bearing for any signs of looseness or abnormal wear.
- Remove scale and sediment from the cooling system to ensure proper heat dissipation.
- Clear carbon deposits from the combustion chamber and intake/exhaust passages.
- Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
- Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
- Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.
Level 3 Maintenance (Every 500-1000 Hours)
Includes Level 1 and Level 2 maintenance tasks, along with additional services:
- Check and adjust the fuel injection timing.
- Clean the fuel tank to remove contaminants.
- Clean the oil sump to prevent sludge buildup.
- Inspect and test the fuel injectors for optimal atomization.
By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.
For more information or to schedule maintenance, contact us today!
1. Are you a factory or a trading company?
We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.
2. What are your main markets?
Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.
3. How do you ensure product quality?
We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.
4. What is your warranty policy?
Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.
5. Can we customize the generator with our logo or design?
Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.
6. What is your delivery time?
Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.
7. How can I become your distributor?
We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.
8. Do you provide after-sales support?
Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.
9: What is the payment terms you can accept?
- A: T/T, 30% deposit, 70% will be paid before delivery;
- or T/, 30% deposit, 70% L/C at sight;
- or 100% L/C at sight;