30KW Cummins Diesel Generator | XN-30CDG - XN-GEN.COM

Power Range/

30KW Cummins Diesel Generator | XN-30CDG

Model: XN-GNE30

Standby Power: 36KW

Rated Power: 33KW

Cylinders/Configuration: 4 / Inline

Compression Ratio: 16.5:1

Bore × Stroke: 102×120 mm

Displacement: 3.9L

Oil Pressure: 345 kPa

Oil Temperature: ≤ 121°C

Oil Capacity: 9L

Coolant Capacity: 7.9L (engine only)

Fuel System: NYC A-type inline pump

Cooling System: Closed-loop water cooling

Governing Method: Electronic

Starting System: DC 24V Electric Start

Air Intake System: Turbocharged

Operation Mode: Four-stroke

Load Stability: ±0.25%

Power Deviation: ≤ ±5%

  • Product Details
  • Maintenance
  • FAQ

Product Overview

The 30KW Cummins Diesel Generator is a highly efficient and reliable power solution designed for industrial, commercial, and emergency backup applications. Equipped with the XN-GNE30 Cummins diesel engine and the PI144H/S1L2-J1 Stamford alternator, this generator ensures superior performance, fuel efficiency, and durability. Operating at 50Hz, it delivers a standby power of 30KW and a prime power of 28KW, making it a perfect choice for continuous and backup power needs.

With a compact and lightweight design, this generator offers cleaner emissions, quieter operation, and lower fuel consumption.

Key Features & Benefits

ISO & GB/T Standards Compliance – Conforms to ISO 8528-2005 and GB/T 2820-2009 standards for reciprocating internal combustion engine-driven AC generators.

Certified Quality & Reliability – Manufactured under ISO9001/ISO9002 certification, ensuring consistent quality and reliability.

Comprehensive Warranty – Backed by 1-year or 1,000-hour warranty covering the engine, alternator, and control system.

Nationwide Service Support – A professional service network providing 24/7 after-sales support and technical assistance.

Heavy-Duty Performance – Built to withstand extreme working conditions with high-strength components and heavy-load capacity.

Advanced Turbocharged Engine – Features a Holset turbocharger for improved power and efficiency.

Integrated Design Fewer parts and reduced connection points lower failure rates and enhance reliability.

Durable Engine Components Forged camshaft and crankshaft ensure superior strength and longevity.

Optimized Fuel System – Features a high-pressure inline fuel pump, reducing fuel consumption and noise levels.

Efficient Cooling System – Closed water-cooled circulation for stable temperature control and extended engine life.

Environmental Requirements

  • Altitude: ≤ 1,000m
  • Fuel Type: 0# Light Diesel
  • Atmospheric Pressure: 89.9 kPa
  • Oil Specification: CF Grade / 15W-40
  • Intake Air Temperature: ≤ 40°C
  • Water pH Level: 6.5 8
  • Humidity: 60%
  • Mold Resistance: GB/T2423.16/2 Level
  • Seismic Resistance: Horizontal acceleration 0.2g / Vertical acceleration 0.1g

Generator Specifications

  • Model: KC30GF
  • Standby Power: 30KW
  • Prime Power: 28KW
  • Dimensions (L×W×H): 1650×800×1260mm
  • Weight: 697kg
  • Speed: 1500 RPM
  • Fuel Consumption: 214 g/KW.h
  • Frequency: 50Hz
  • Voltage Stability: ≤ ±1%
  • Transient Voltage Deviation: -15% / +20%
  • Voltage Recovery Time: 3 sec
  • Voltage Fluctuation Rate: 0.5%
  • Harmonic Distortion (THD): 8%
  • Steady-State Frequency Regulation: 5%
  • Transient Frequency Regulation: -10% / +12%
  • Frequency Recovery Time: 3 sec
  • Frequency Fluctuation Rate: 1.5%

Engine Specifications

  • Brand: Cummins
  • Manufacturer: Dongfeng Cummins Engine Co., Ltd. (DCEC)
  • Model: XN-GNE30
  • Standby Power: 36KW
  • Rated Power: 33KW
  • Cylinders/Configuration: 4 / Inline
  • Compression Ratio: 16.5:1
  • Bore × Stroke: 102×120 mm
  • Displacement: 3.9L
  • Oil Pressure: 345 kPa
  • Oil Temperature: ≤ 121°C
  • Oil Capacity: 9L
  • Coolant Capacity: 7.9L (engine only)
  • Fuel System: NYC A-type inline pump
  • Cooling System: Closed-loop water cooling
  • Governing Method: Electronic
  • Starting System: DC 24V Electric Start
  • Air Intake System: Turbocharged
  • Operation Mode: Four-stroke
  • Load Stability: ±0.25%
  • Power Deviation: ≤ ±5%

Alternator Specifications

  • Brand: Stamford
  • Manufacturer: Cummins Generator Technologies (China) Co., Ltd.
  • Model: PI144H/S1L2-J1
  • Capacity: 35KVA
  • Voltage: 400V/230V
  • Design: Brushless, Single Bearing, Rotating Magnetic Field
  • Excitation System: Self-excited, AVR-controlled
  • Winding Configuration: 2/3 Pitch
  • Phases: 3-Phase, 4-Wire
  • Insulation Class: H
  • Power Factor: 0.8 Lagging
  • Telephone Interference Factor (TIF): <50
  • Harmonic Distortion (THF): <2%
  • Connection Type: Y-Configuration
  • Protection Level: IP23
  • Radio Interference Compliance: Meets BS800 & VDE G/N Standards
  • Standards Compliance: GB755, BS5000 Part 3, VDE0530, NEMA MG1-22, IEC-34, GSA C22-100, AS1359

Standard Inclusions

  • Engine Components: Engine, Diesel Filter, Air Filter, Oil Filter, Charging Alternator, Starter Motor.
  • Alternator Components: Stamford Alternator, Circuit Breaker.
  • Control System: LCD Digital Controller, Electronic Governor.
  • Other Components: Radiator, Steel Base Frame, Vibration Mounts.
  • Accessories: Silencer, Battery, Battery Cables, Engine Oil, Anti-Vibration Pads.

Certifications & Compliance

  • Military Standard: GJB 5785-2006
  • National Standard: GB/T 2820-2002
  • Telecom Standard: YD/T 502-2007
  • Industry Standard: JB/T 10303-2001
  • Environmental Certifications: Noise & Emission Class A
  • TL Certification: YD/T502-2007

Why Choose the 30KW Cummins Diesel Generator?

  • High Durability & Reliability – Engineered for long-term performance.
  • Fuel Efficiency – Low fuel consumption with high power output.
  • Comprehensive Service Support 24/7 technical assistance and nationwide coverage.
  • Advanced Control System – LCD digital monitoring for easy operation.
  • Strict Quality Control – Meets international and industrial standards.

Product configuration and details

Successful Project

Successful Project

Logistics Packaging

Get in Touch

For more details, pricing, or inquiries about the 30KW Cummins Diesel Generator, contact us today! Our experts are ready to help you find the perfect power solution for your needs.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Leave a message