The 20Мобільний портативний дизельний генератор KW is a top-tier power solution designed for industrial, commercial, and emergency backup applications. Powered by a robust Cummins 4B3.9-G2 engine and paired with a Stamford PI142D/S0L2-M1 alternator, this generator delivers exceptional efficiency, durability, and reliability. With an integrated four-wheel trailer, it ensures mobility and ease of transport, making it an ideal choice for various power needs.
Key Features
Superior Build & Design
- Compact & Sturdy Construction – Built with a corrosion-resistant and weatherproof enclosure, ensuring long-term durability in challenging environments.
- Easy Installation & Maintenance – Designed for hassle-free setup, with a detachable soundproof cover for quick maintenance access.
- Anti-Theft & Anti-Corrosion Protection – Multi-layer protective coatings enhance resistance against environmental elements.
- Low Noise Operation – Soundproofing technology reduces noise levels to 70-85dB at 7 meters.
Powerful Performance
- Backup Power: 20KW (Standby Power) / 18KW (Rated Power)
- High Fuel Efficiency: Consumes 216 g/kw.h, reducing operational costs.
- Advanced Control System: LCD digital display for real-time monitoring and control.
- Electronic Governor System: Ensures stable performance and minimal voltage fluctuations (±1% stability).
- Heavy-Duty Load Handling: With a peak power tolerance of +20%/-15% transient voltage adjustment.
Reliable Cummins Engine
- Engine Model: Cummins 4B3.9-G2
- Power Output: 24KW
- Four-Cylinder, Four-Stroke Diesel Engine with direct injection for optimal efficiency.
- Electronic Fuel System: NYC A-type inline pump for enhanced fuel efficiency.
- Water-Cooled System: Closed-loop cooling for efficient temperature regulation.
- Long-Lasting Durability: Made with forged steel crankshaft and high-strength cylinder block for extended lifespan.
- Compression Ratio: 16.5:1 for optimal combustion.
- Low Oil Consumption: 9L engine oil capacity with a high-performance lubrication system.
Stamford Alternator – High Efficiency & Stability
- Alternator Brand: Stamford
- Model: PI142D/S0L2-M1
- Capacity: 25KVA (Rated) / 27.5KVA (Maximum)
- Voltage Output: 400V/230V
- Brushless Alternator: Reduces maintenance costs and improves lifespan.
- Self-Excited, AVR Control: Ensures stable voltage regulation and efficient power output.
- High-Quality Insulation (H Class): Ensures durability and resistance to temperature variations.
- IP23 Protection: Shields against dust and water ingress.
Environmental & Operating Conditions
- Altitude: ≤1000m
- Ambient Temperature: ≤40°C
- Relative Humidity: ≤60%
- Fuel Type: 0# Light Diesel
- Lubricant Standard: CF grade / 15W-40
- Seismic Resistance: Horizontal acceleration 0.2g, vertical acceleration 0.1g
Dimensions & Specifications
- Model: XN20KW Mobile Diesel Generator
- Size: 2400mm x 1550mm x 1800mm
- Weight: 1500kg
- Speed: 1500 RPM
- Voltage Stability: ≤0.5% fluctuation rate
- Frequency Stability: ≤1.5% fluctuation rate
- Startup Mode: DC24V Electric Start
Standard Accessories
- Engine Components: Diesel engine, oil filter, air filter, fuel filter, battery charger, starter motor.
- Alternator System: Stamford alternator with integrated air switch.
- Control System: LCD digital controller with electronic speed control.
- Additional Equipment: Silencer, battery, anti-vibration mounting pads, steel frame base.
Compliance & Certifications
- ISO 8528-2005 & GB/T 2820-2009 Compliant
- Military Standard: GJB 5785-2006
- National Standard: GB/T 2820-2002
- Telecommunication Standard: YD/T 502-2007
- Industrial Standard: JB/T 10303-2001
- Environmental Certification: Noise & Emission Grade A
- TÜV & CE Certified for quality assurance
Додатків
The 20KW Mobile Diesel Generator is suitable for a wide range of applications, including:
- Construction Sites – Reliable power for tools and equipment.
- Emergency Backup Power – Ensures uninterrupted power supply.
- Outdoor Events – Portable and easy to deploy.
- Industrial & Agricultural Use – Heavy-duty operations with stable performance.
- Telecommunications – Powering base stations and critical infrastructure.
Why Choose This Generator?
✅ High-Quality Cummins Engine & Stamford Alternator
✅ Fuel-Efficient & Low Emission
✅ Heavy-Duty Performance for Continuous Operation
✅ Superior Noise Reduction & Weatherproof Design
✅ Easy Mobility with Integrated Trailer System
✅ Comprehensive Warranty & 24/7 Technical Support
OPTIONAL FUNCTION

Contact Us
📧 Email: [ gmail@xn-gen.com]
📞 Phone: [+86 15216161715]
🌐 Website: [xn-gen.com]
For more information or to discuss your specific energy requirements, please contact our sales team. We are committed to delivering efficient and reliable power solutions tailored to your project needs.
Generator Maintenance and Servicing
At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).
Routine Maintenance
Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:
- Inspect all rotating components and tighten any loose bolts.
- Check the oil level in the crankcase and add oil if necessary.
- Monitor fuel levels in the tank.
- Inspect the coolant level in the radiator.
- Examine fuel and water pipelines for any leaks or loose connections.
- Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
- Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.
Maintenance Plan for Standby Generators
(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)
Professional Maintenance (Every Six Months or Annually)
In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:
- Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
- Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
- Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
- Drain and replace coolant, ensuring proper radiator function.
- Check and replenish the battery electrolyte or distilled water as needed.
- After completing the maintenance, conduct a final inspection and clean the generator set.
- Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.
Maintenance Plan for Continuous Operation Generators
(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)
Level 1 Maintenance (Every 50-80 Hours)
This includes all routine maintenance tasks plus:
- Clean the air filter and replace it if necessary.
- Replace the diesel filter, air filter, and water filter.
- Inspect the tension of the drive belt and adjust if needed.
- Lubricate all grease fittings and moving components.
- Replace coolant to maintain effective cooling performance.
Level 2 Maintenance (Every 250-300 Hours)
Includes Level 1 maintenance tasks, with additional checks:
- Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
- Examine the main bearing for any signs of looseness or abnormal wear.
- Remove scale and sediment from the cooling system to ensure proper heat dissipation.
- Clear carbon deposits from the combustion chamber and intake/exhaust passages.
- Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
- Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
- Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.
Level 3 Maintenance (Every 500-1000 Hours)
Includes Level 1 and Level 2 maintenance tasks, along with additional services:
- Check and adjust the fuel injection timing.
- Clean the fuel tank to remove contaminants.
- Clean the oil sump to prevent sludge buildup.
- Inspect and test the fuel injectors for optimal atomization.
By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.
For more information or to schedule maintenance, contact us today!
1. Are you a factory or a trading company?
We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.
2. What are your main markets?
Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.
3. How do you ensure product quality?
We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.
4. What is your warranty policy?
Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.
5. Can we customize the generator with our logo or design?
Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.
6. What is your delivery time?
Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.
7. How can I become your distributor?
We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.
8. Do you provide after-sales support?
Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.
9: What is the payment terms you can accept?
- A: T/T, 30% deposit, 70% will be paid before delivery;
- or T/, 30% deposit, 70% L/C at sight;
- or 100% L/C at sight;