800เครื่องกําเนิดไฟฟ้าดีเซล KW Cummins | XN-800CDG - XN-GEN.COM

ช่วงพลังงาน/

800เครื่องกําเนิดไฟฟ้าดีเซล KW Cummins | XN-800CDG

Model: XN-800CDG

Standby Power: 800KW

Rated (Continuous) Power: 720KW

Operating Frequency: 50Hz

Dimensions (LxWxH): 4100 x 1760 x 2400 mm

Weight: 7200 kg

Engine Speed: 1500 r/min

Fuel Consumption: Approximately 209 g/kW.h

  • Product Details
  • Maintenance
  • FAQ

Product Overview

The 800KW Cummins Diesel Generator is engineered for high performance and long-term reliability. Powered by a robust KTA38-G2A Cummins diesel engine and paired with a state-of-the-art Stamford generator, this unit delivers a standby power output of 800KW (with a typical load of 720KW) at a steady 50Hz frequency. Designed with a focus on operational efficiency and environmental compliance, it meets rigorous international standards including ISO8528-2005 and GB/T2820-2009.

Key Features

  • Advanced Engine Technology:
    Utilizes a high-strength alloy cast iron block and a four-valve per cylinder head design for optimal combustion efficiency and reduced emissions.

  • Robust Construction:
    Features a precision-machined single-camshaft for accurate timing control and a fully forged crankshaft with induction hardening to ensure superior fatigue strength.

  • Optimized Cooling and Exhaust System:
    Integrated wet-type turbocharger and water-cooled exhaust pipes lower engine surface temperatures while meeting SOLAS safety regulations. Additionally, the air-to-air intercooling technology enhances fuel economy and emission performance.

  • Global Standards:
    Adheres to the stringent quality and performance standards of Cummins, with manufacturing and testing protocols that ensure consistent reliability under continuous, standby, and peak load conditions.

  • Comprehensive Support:
    Backed by a 1-year or 1000-hour warranty, the generator is supported by an extensive network offering 24/7 technical assistance and after-sales service.

Technical Specifications

General Generator Data

  • Model: XN-800CDG

  • Standby Power: 800KW

  • Rated (Continuous) Power: 720KW

  • Operating Frequency: 50Hz

  • Dimensions (LxWxH): 4100 x 1760 x 2400 mm

  • Weight: 7200 kg

  • Engine Speed: 1500 r/min

  • Fuel Consumption: Approximately 209 g/kW.h

Electrical Performance

  • Transient Voltage Regulation: –15% / +20%

  • Steady-State Voltage Regulation: ±1%

  • Voltage Stabilization Time: ≤3 seconds

  • Voltage Fluctuation: ≤0.5%

  • Harmonic Distortion: ≤8%

  • Frequency Regulation:

    • Steady-State: ≤5%

    • Transient: –10% / +12%

    • Stabilization Time: 3 seconds

    • Fluctuation: ≤1.5%

Engine Specifications

  • Engine Model: Cummins KTA38-G2A

  • Configuration: 12-cylinder V-type

  • Compression Ratio: 14.5:1

  • Bore x Stroke: 159 x 159 mm

  • Displacement: 37.8 L

  • Rated Output Power: 813KW (with a standby power capability of 895KW)

  • Oil Pressure: 45–65 psi

  • Maximum Oil Temperature: ≤121°C

  • Oil Capacity: 135 L

  • Coolant Capacity: 263 L

  • Fuel System: Direct injection via PT pump

  • Cooling Method: Closed-loop water cooling

  • Starting System: DC24V electric starter

  • Control: Electronic speed regulation

  • Induction: Turbocharged with intercooling for optimal air-fuel mixture

Generator Specifications

  • ยี่ห้อ: Stamford

  • Models: S6L1D-D41 / HCI634H1 / LVI634D1

  • Rated Capacity: Up to 940 KVA

  • Voltage Options: 400V/230V

  • Design: Brushless with a single bearing and rotating magnetic field

  • Excitation System: Self-excited with automatic voltage regulation

  • Winding Structure: 2/3 pitch

  • Phases: Three-phase, four-wire

  • Insulation Class: H

  • Power Factor: 0.8 (lagging)

  • Protection Level: IP23

  • Compliance: Meets GB755, BS5000 Part III, VDE0530, NEMA MG1-22, IEC-34, GSA C22-100, and AS1359 standards

Standard Configuration

Engine Components

  • Cummins diesel engine with integrated fuel, oil, and air filters

  • Battery charger and electric starter

Generator Components

  • Stamford generator unit paired with an air circuit breaker

Control System

  • LCD digital display controller with an electronic governor

Additional Equipment

  • Radiator with water tank, heavy-duty steel base, and vibration dampening mounts

  • Muffler, battery system, battery cables, oil, and seismic pads

Certifications and Compliance

  • International Standards: Complies with ISO8528-2005 and GB/T2820-2009 for reciprocating engine-driven AC generator sets.

  • Quality Assurance: Manufactured under ISO9001/ISO9002 certified processes.

  • Environmental & Safety: Meets SOLAS safety regulations and achieves top marks for noise and emissions compliance.

Optional Accessories

To enhance operational versatility, the 800KW Cummins Diesel Generator can be equipped with:

  • ATS (Automatic Transfer Switch) for seamless load switching

  • Deep-sea DSE control module for parallel operation

  • Containerized design for compact installations

  • Mobile trailer-mounted power stations

  • Rainproof and soundproof enclosures

  • Remote microprocessor interface for advanced monitoring

Operating Environment

Designed for reliable performance in diverse environmental conditions, this generator is suitable for:

  • Altitudes up to 1000 meters

  • Ambient temperatures of ≤40°C

  • Relative humidity levels of ≤60%

  • Applications that require compliance with both maritime and land-based operational standards

Elevate your power backup solutions with the 800KW Cummins Diesel Generator—a perfect blend of cutting-edge engineering, global quality standards, and unmatched support for demanding applications. For further details or to request a quote, please contact our sales team.

OPTIONAL FUNCTION

Logistics Packaging

Elevate your power backup solutions with the 800KW Cummins Diesel Generator—a perfect blend of cutting-edge engineering, global quality standards, and unmatched support for demanding applications. For further details or to request a quote, please contact our sales team.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply