800KW Gerador Diesel | XN-800GFS - XN-GEN.COM

Faixa de potência/

800KW Gerador Diesel | XN-800GFS

Model: XN-800GFS

Rated Voltage: 400/230V (3-Phase)

Rated Current: 1440A

Frequency: 50Hz (Customizable to 60Hz)

Dimensions: 4950×1780×2250mm (L×W×H)

Weight: 6380kg

  • Product Details
  • Maintenance
  • FAQ

800KW diesel generator designed for industrial backup and prime power needs. Featuring ISO-certified engines, advanced control systems, and global compliance. Explore specs, features, and custom options today.

Key Features

  • Power Output: 800KW (1000KVA) Prime | 880KW (1100KVA) Standby
  • Fuel Efficiency: 161L/h at full load (Industry-leading consumption rate)
  • Durability: Heavy-duty V6 engine with turbocharged intercooling
  • Compliance: Meets ISO 3046, ISO 8528, IEC 34-1, and BS 5000 standards
  • Smart Control: HGM6110 Auto Control System with real-time monitoring

Technical Specifications

Generator Set Overview

  • Model: XN-800GFS
  • Rated Voltage: 400/230V (3-Phase)
  • Rated Current: 1440A
  • Frequency: 50Hz (Customizable to 60Hz)
  • Dimensions: 4950×1780×2250mm (L×W×H)
  • Weight: 6380kg

Advanced Diesel Engine

  • Engine Model: 6WTAA35-G31
  • Power Rating: 882KW (Prime) / 970KW (Standby)
  • RPM: 1500 | Cylinders: 6 (V-Type)
  • Bore x Stroke: 186mm x 215mm | Displacement: 35.1L
  • Air Intake: Turbocharged, Air-to-Air Intercooled
  • Cooling System: Closed-loop freshwater cooling
  • Exhaust Temp: ≤600°C | Fuel System: Electronic Governing

High-Efficiency Alternator

  • Brand: XN Synchronous Alternator
  • Efficiency: 93.7% | Power Factor: 0.8 Lagging
  • Voltage Regulation: ±1% (Brushless Self-Excitation)
  • Protection Rating: IP23 | Insulation Class: H
  • Certifications: GB755, VDE0530, AS2359, CSA22.2

Intelligent Control System

  • Controller: HGM6110 Auto Control Module
  • Monitoring: LED display for voltage, frequency, oil pressure, coolant temp, and battery status.
  • Safety Alarms: Overload, low oil pressure, high temperature, and overspeed protection.
  • Battery: 2x 150Ah 12V (Pre-wired for quick start)

Operating Conditions:

  • Altitude: ≤1000m
  • Ambient Temp: ≤40°C
  • Humidity: ≤60% RH

Optional Add-Ons

  • ATS (Automatic Transfer Switch): Seamless power transition during outages.
  • Parallel Control System: DSE-based synchronization for multi-unit operation.
  • Custom Enclosures: Weatherproof canopy, soundproof models, or mobile trailer units.
  • Remote Monitoring: PC/Cloud interface for real-time diagnostics.

Technical drawings:

Technical drawings:

Successful Project

Successful Project

Logistics Packaging

Request a Quote or Custom Configuration Today!

Upgrade to the XN-800GFS diesel generator for unmatched power efficiency, durability, and compliance with industrial demands. Contact us for bulk pricing or customized configurations.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Leave a message