1800KW Cummins Diesel Generator | XN-1800CDG - XN-GEN.COM

Power Range/

1800KW Cummins Diesel Generator | XN-1800CDG

Brand: Cummins

Model: XN-1800CDG

Manufacturer: Chongqing Cummins Engine Co., Ltd.

Configuration: 16-cylinder,

V-type 4-stroke

Displacement: 50.3L

Compression Ratio: 14.7:1

Bore x Stroke: 159mm x 159mm

Max Power Output: 1972KW

Rated Power: 1784KW

 

  • Product Details
  • Maintenance
  • FAQ

High-Performance Power Solution

The 1800KW Cummins Diesel Generator is a premium power solution designed for reliable, efficient, and continuous operation. Powered by the XN-1800CDG Cummins diesel engine, coupled with the S7L1D-G41/PI734F1 Stamford alternator, this generator ensures optimal performance for industrial, commercial, and emergency backup applications.

Key Features

  • Powerful Performance: Provides 1800KW standby power and 1600KW prime power at 50Hz frequency.
  • Advanced Engine Technology: Features a four-valve structure, ultra-high fuel injection pressure, and an optimized combustion system for maximum efficiency and lower emissions.
  • Reliable Under Various Conditions: Designed to perform exceptionally in diverse environmental and load conditions.
  • Global Standards Compliance: Conforms to ISO 8528-2005 and GB/T 2820-2009 standards.
  • Robust Quality Assurance: Certified under ISO9001/ISO9002 with a 1-year or 1000-hour comprehensive warranty.
  • 24/7 Customer Support: Nationwide service network offering round-the-clock technical assistance.

Engine Specifications

  • Brand: Cummins
  • Model: XN-1800CDG
  • Manufacturer: Chongqing Cummins Engine Co., Ltd.
  • Configuration: 16-cylinder, V-type, 4-stroke
  • Displacement: 50.3L
  • Compression Ratio: 14.7:1
  • Bore x Stroke: 159mm x 159mm
  • Max Power Output: 1972KW
  • Rated Power: 1784KW
  • Cooling System: Closed-loop water cooling
  • Fuel System: ECM-controlled high-pressure common rail
  • Start System: DC 24V electric start
  • Speed Control: Electronic governor for precise frequency regulation

Generator Specifications

  • Brand: Stamford
  • Model: S7L1D-G41/PI734F1
  • Rated Capacity: 2080KVA
  • Voltage Output: 400V/230V
  • Configuration: Brushless, single-bearing, rotating magnetic field
  • Excitation System: Self-excited, automatic voltage regulation (AVR)
  • Winding Structure: 2/3 pitch design to minimize harmonic distortion
  • Insulation Class: H-class
  • Power Factor: 0.8 (lagging)
  • Protection Level: IP23

Operational Performance

  • Rated Speed: 1500 rpm
  • Fuel Consumption: 193 g/KW.h
  • Voltage Stability: ≤ ±1%
  • Transient Voltage Regulation: -15% / +20%
  • Voltage Recovery Time: 3 sec
  • Voltage Fluctuation: 0.5%
  • Frequency Stability: 1.5%
  • Cold Start Capability: Operates at temperatures as low as -7°C without auxiliary devices

Environmental Conditions

  • Altitude: ≤1000m
  • Fuel Type: 0# Light Diesel
  • Atmospheric Pressure: ≥89.9 kPa
  • Oil Standard: CF Grade / 15W-40
  • Air Temperature: ≤40°C
  • Relative Humidity: ≤60%
  • Vibration Resistance: Horizontal acceleration 0.2g, vertical acceleration 0.1g

Standard Components

  • Engine System: Diesel engine, fuel filter, air filter, oil filter, starter motor, alternator
  • Generator System: Stamford alternator, circuit breaker
  • Control System: LCD digital control panel, electronic governor
  • Cooling System: Radiator, centrifugal water pump, rotating water filter
  • Accessories: Silencer, batteries, battery cables, anti-vibration mounts, engine oil

Certifications & Compliance

  • Military Standard: GJB 5785-2006
  • National Standard: GB/T 2820-2002
  • Telecom Standard: YD/T 502-2007
  • Industry Standard: JB/T 10303-2001
  • Environmental Certifications: Noise & emissions Class A
  • TLC Quality Certification: YD/T 502-2007

Why Choose the 1800KW Cummins Diesel Generator?

  • High Efficiency & Low Emissions – Advanced combustion technology minimizes fuel consumption and exhaust emissions.
  • Exceptional Reliability – Built for durability, ensuring continuous and standby power solutions.
  • Seamless Integration – Designed to fit within industrial, commercial, and critical power infrastructures.
  • Global Service & Support – Extensive Cummins service network offering rapid maintenance and technical assistance.

Technical drawings:

Technical drawings:

Successful Project

Successful Project

Logistics Packaging

Get in Touch

For more details, pricing, or inquiries about the 1800KW Cummins Diesel Generator, contact us today! Our experts are ready to help you find the perfect power solution for your needs.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Leave a message