Weichai Diesel Generator Sets 2500KVA-3025KVA - XN-GEN.COM

Power Range/

Weichai Diesel Generator Sets 2500KVA-3025KVA

Prime Power: 2,000 kWe

Standby Capacity: 2,750 kVA

Engine Output: 2,200 kWm (prime) / 2,450 kWm (standby)

(other specs identical to WPG2500B73)

Wet Weight†: 22,000 kg

  • Product Details
  • Maintenance
  • FAQ

The Weichai 2500 – 3025 kVA Diesel Generator Sets deliver industry‑leading performance, robustness, and fuel efficiency for critical power applications. Engineered around the proven 12M55 engine and WHA series alternator, they provide both prime and standby power for data centers, hospitals, industrial sites, and construction projects.

Key Benefits

  • High Power Density: Outputs ranging from 2,500 to 3,025 kVA in a compact skid‑mount footprint.

  • Advanced Fuel System: Electronic high‑pressure common‑rail injection achieves fuel consumption of ≤ 192 g/kW·h at prime load.

  • Durable Construction: Closed‑loop forced water cooling, heavy‑duty bearings, and cast‑iron blocks ensure long life under continuous operation.

  • Comprehensive Protection: Integrated engine ECU and genset controller guard against overload, over‑speed, high coolant temperature, and low oil pressure.

  • Flexible Integration: Available in open‑frame or weather‑protected canopy variants, with customizable fuel tanks, sound insulation, and exhaust configurations.

  • Global Compliance: CE‑certified and meeting China Stage III (equivalent EU Stage IIIA) emission standards.

Model Specifications

WPG2500B73

  • Prime Power: 1,800 kWe

  • Standby Capacity: 2,500 kVA

  • Engine Output: 1,985 kWm (prime) / 2,210 kWm (standby)

  • Engine: Weichai 12M55, 12 cylinders, 65.65 L displacement

  • Alternator: WHA series, brushless, class H insulation

  • Speed: 1,500 rpm (electronic governor)

  • Cooling: Closed‑loop forced water

  • Fuel Consumption: ≤ 192 g/kW·h

  • Dimensions (L×W×H): 6,600 × 2,680 × 2,980 mm

  • Wet Weight†: 21,100 kg

WPG2750B73

  • Prime Power: 2,000 kWe

  • Standby Capacity: 2,750 kVA

  • Engine Output: 2,200 kWm (prime) / 2,450 kWm (standby)

  • (other specs identical to WPG2500B73)

  • Wet Weight†: 22,000 kg

WPG3025B73

  • Prime Power: 2,200 kWe

  • Standby Capacity: 3,025 kVA

  • Engine Output: 2,420 kWm (prime) / 2,700 kWm (standby)

  • (other specs identical to WPG2500B73)

  • Wet Weight†: 22,400 kg

† Includes engine oil and coolant.

Product Features

  1. Industry-Leading Performance

    • Stable voltage and frequency under fluctuating loads

    • Rapid transient response for dynamic power demands

  2. Advanced Protection & Control

    • Onboard ECU diagnostics with real‑time data logging

    • Comprehensive alarm/shutdown functions for engine and alternator

  3. Modular & Service‑Friendly Design

    • Skid‑mounted base with integrated fuel trays

    • Easily accessible service points for filters, belts, and pumps

  4. Emission Compliance

    • Meets China Stage III / EU Stage IIIA standards

    • CE certification for international deployment

  5. Customizable Configurations

    • Open‑frame, sound‑attenuated canopy, or containerized options

    • Optional remote monitoring and auto‑start panels

Typical Applications

  • Data Centers & IT Facilities – Ensures uninterrupted operation of servers and networking equipment.

  • Healthcare & Hospitals – Backup power for life‑safety systems, imaging, and critical care units.

  • Industrial & Manufacturing Plants – Supports heavy machinery and process controls.

  • Oil & Gas Installations – Reliable power in remote or offshore locations.

  • Construction & Mining – Mobile and stationary solutions for power‑hungry equipment.

  • Commercial Complexes – Standby power for offices, shopping centers, and residential buildings.

Why Choose Weichai?

  • Decades of Expertise: Over 70 years in engine development and power generation.

  • Global Support Network: Local distributors and service centers in 100+ countries.

  • Turnkey Solutions: From system design and integration to commissioning and maintenance.

  • Cost‑Effective Operation: Low lifecycle costs through high efficiency and robust components.

  • 24/7 Technical Assistance: Remote diagnostics, parts supply, and field service teams.

Contact Us

For detailed quotations, technical consultations, or factory visits, please reach out to your nearest Weichai distributor or our global sales team:

  • Email: gmail@xn-gen.com

  • Phone: +86 15216161715

  • Web: xn-gen.com

Experience dependable, high‑quality power with the Weichai 2500 – 3025 kVA Diesel Generator Series.

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply