180KW Silent Diesel Generator - XN-GEN.COM

Applications/

180KW Silent Diesel Generator

Model: XN180SDG

Type: Silent Diesel Generator

Standby Power: 180kW

Prime Power: 160kW

Dimensions (L x W x H): 3500mm x 1300mm x 2000mm

Weight: 3240kg

Noise Level: 70-85dB at 7m

Fuel Consumption: 210g/kW.h

Speed: 1500rpm

  • Product Details
  • Maintenance
  • FAQ

Product Overview

The 180KW Silent Diesel Generator is a premium power solution engineered for reliability, efficiency, and quiet operation. Featuring a Cummins 6CTAA8.3-G2 diesel engine and a Stamford UCI274H alternator, this generator is housed in an advanced soundproof enclosure, making it perfect for noise-sensitive settings like residential areas, offices, or hospitals. With a standby power output of 180kW and a prime power output of 160kW, it delivers consistent performance for both emergency backup and continuous use.

Key Benefits

  • Whisper-Quiet Design: Noise levels reduced to 70-85dB at 7 meters thanks to a multi-layered soundproof canopy and advanced silencing technology.
  • Robust Power: Combines a trusted Cummins engine and Stamford alternator for dependable electricity generation.
  • Fuel-Saving Technology: Bosch inline fuel pump ensures efficient combustion, lowering fuel costs and adapting to various fuel types.
  • Built to Last: Fewer components and durable materials reduce maintenance needs and extend lifespan.
  • Easy Operation: Intuitive LCD digital controller and electronic speed regulation for hassle-free monitoring and control.

Technical Specifications

General Specifications

Parameter Details
Model XN180SDG
Type Silent Diesel Generator
Standby Power 180kW
Prime Power 160kW
Dimensions (L x W x H) 3500mm x 1300mm x 2000mm
Weight 3240kg
Noise Level 70-85dB at 7m
Fuel Consumption 210g/kW.h
Speed 1500rpm

Engine Specifications

Parameter Details
Brand Cummins
Model 6CTAA8.3-G2
Standby Power 200kW
Cylinders 6, inline
Displacement 8.3L
Bore x Stroke 114mm x 135mm
Compression Ratio 16.5:1
Fuel System PB inline pump
Cooling Closed water cooling cycle
Starting Method DC24V electric start

Alternator Specifications

Parameter Details
Brand Stamford
Model UCI274H
Capacity 220KVA
Voltage 400V/230V
Type Brushless, single bearing
Insulation Class H
Protection Level IP23
Power Factor COSΦ=0.8 (lagging)

Performance Metrics

  • Voltage Regulation: Steady-state ≤±1%, Transient ≤-15%/+20%
  • Frequency Regulation: Steady-state ≤5%, Transient ≤-10%/+12%
  • Stabilization Time: Voltage ≤3s, Frequency 3s
  • Waveform Distortion: ≤8%

Advanced Features

  • Soundproofing Excellence: High-performance shock absorbers and 4-5 layers of sound-absorbing materials in the canopy minimize vibration and noise.
  • Innovative Airflow: A labyrinth-style air intake silencer ensures ample fresh air while blocking sound transmission.
  • Exhaust Noise Reduction: Impedance composite muffler significantly lowers exhaust noise for a quieter operation.
  • Standard Components: Includes water tank radiator, steel base, vibration pads, muffler, battery, and more for seamless setup.

Performance Highlights

  • Precision Engineering: Advanced design and meticulous manufacturing ensure long-term durability and reliability.
  • Optimized Fuel Delivery: The Bosch inline pump provides high-pressure injection for cleaner combustion and stronger power output.
  • Turbocharged Efficiency: Holset turbocharger with wastegate valve enhances low-speed response and overall performance.
  • Simplified Maintenance: 25% fewer parts compared to similar models, reducing downtime and repair costs.
  • Longevity: Plateau-honed cylinder liners and high-nickel cast iron pistons cut oil use and boost engine life.

Warranty and Support

Cummins backs this generator with a 1-year or 1000-hour warranty, covering the engine, alternator, and control system. Our nationwide service network offers 24/7 technical support and after-sales assistance, ensuring your power needs are always met.

Standards and Certifications

  • Quality Standards: ISO8528-2005, GB/T2820-2009
  • Manufacturing Certifications: ISO9001, ISO9002
  • Military Standard: GJB 5785-2006
  • Industry Standards: JB/T 10303-2001, YD/T 502-2007
  • Environmental Compliance: Class A for noise, vibration, and emissions

Operating Conditions

For peak performance, use within these parameters:

  • Altitude: ≤1000m
  • Fuel Type: 0# light diesel
  • Oil Type: CF grade/15W-40
  • Intake Temperature: ≤40℃
  • Humidity: ≤60%
  • Seismic Resistance: Horizontal 0.2g, Vertical 0.1g

Why Choose This Generator?

The 180KW Silent Diesel Generator combines cutting-edge technology with practical design, delivering quiet, efficient, and reliable power. Whether you need a backup for emergencies or a steady source for ongoing operations, this generator offers unmatched value with its low noise, fuel efficiency, and robust support. Ready to power your world? Contact us today!

Get in Touch

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Ready to power your space with the XN300SDG Silent Diesel Generator? Contact us today for more details or to request a personalized quote. Enjoy reliable, quiet power tailored to your needs.

 

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Leave a message