50kW Diesel Generator Emergency Power Supply - XN-GEN.COM

Power Range/

50kW Diesel Generator Emergency Power Supply

Rated Power: 50KW / 62.5KVA

Standby Power: 55KW / 68.75KVA

Frequency Options: 50Hz / 60Hz

Speed: 1500rpm / 1800rpm

Voltage Options: 400-380V, 240-220V, 130-110V

Phase: Available in Three-phase or Single-phase

Starting Method: Automatic Start

Type: Open or Silent Type

Optional Configurations: Trailer, Container, ATS , Heater

  • Product Details
  • FAQ
  • Maintenance

Product Specifications

No Item Data
1 Power 50KW / 62.5KVA
2 Engine Model SC4H95D2
3 Number of Cylinders 4
4 Engine Displacement 4.3L
5 Oil Capacity 13L
6 Alternator YLW-50
7 Dimensions (L×W×H) 1900 × 800 × 1200 mm
8 Weight 950kg

PRODUCT DETAILS

SIMPLE OPERATING MANUAL

SIMPLE OPERATING MANUAL

Application Scenarios

Application Scenarios

Key Specifications

  • Rated Voltage: 110V, 220V, 230V, 240V, 380V
  • Rated Current: 90A
  • Frequency: 50/60Hz
  • Model: SC4H95D2
  • Operating Speed: 1500 RPM
  • Starting System: 24V DC Electric Start
  • Design Type: Open Frame
  • Cooling System: Water-Cooled

This XN-GEN 50kW diesel generator is a powerful, efficient, and long-lasting solution for businesses, industrial facilities, and emergency power backup needs. With its high-performance engine, versatile voltage options, and user-friendly maintenance design, it stands as a reliable investment for uninterrupted power supply.

Dependable Power Source

The 50kW diesel generator from XN-GEN, powered by a SC4H95D2 diesel engine, delivers a stable and reliable power supply, making it ideal for both emergency backup and primary power generation. Whether for commercial, industrial, or critical applications, this generator ensures continuous operation of essential equipment.

Versatile Voltage Compatibility

Designed for flexibility, this diesel generator supports multiple voltage outputs, including 110V, 220V, 230V, 240V, and 380V, catering to a wide range of regional and operational requirements. This makes it suitable for various businesses, factories, and emergency power needs.

High Efficiency & Performance

With an operating speed of 1500 RPM and a water-cooling system, this generator is engineered for efficient performance, minimizing fuel consumption and operational downtime. The advanced cooling mechanism ensures optimal thermal regulation, prolonging engine life and maximizing productivity.

Easy Maintenance & User-Friendly Design

Featuring an open-frame design, this diesel generator allows for easy access to components, reducing maintenance time and costs. Its modular layout facilitates quick inspections, repairs, and servicing, ensuring uninterrupted operation.

Durable & Heavy-Duty Construction

Built with high-quality materials, the XN-GEN 50kW diesel generator is designed for heavy-duty use, ensuring long-term durability even in demanding conditions. Its robust construction minimizes the need for frequent replacements, providing an extended lifespan and enhanced reliability.

Successful Project

Successful Project

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

Prev:

Next:

Leave a Reply

Leave a message