The 1000kW/1250kVA Diesel Generator is a powerful and reliable solution for industrial and commercial power needs. Designed for continuous and standby applications, this generator ensures stable and efficient performance, even in demanding environments. Equipped with advanced features such as an automatic start system and a water-cooled mechanism, it provides excellent durability and efficiency.

Technical Specifications

Specification Details
Power Output 1000kW / 1250kVA
Engine Model 12M33D1210E200
Number of Cylinders 12
Engine Capacity 39L
Oil Capacity 468L
Alternator Model YLW-1000
Speed 1500 RPM / 1800 RPM
Cooling System Water-cooled
Starting System Automatic
Voltage Options 220V, 230V, 240V, 380V, 400V, 415V
Frequency 50Hz / 60Hz
Product Dimensions 5800mm x 2100mm x 2550mm
Weight 12,000 kg

PRODUCT CONFIGURATION

1000KW/1250KVA

SALES AND SERVICE NETWORK

Key Features

  • High Power Output: 1000kW (1250kVA), delivering consistent and reliable energy.
  • Voltage Options: Available in 220V, 230V, 240V, 380V, 400V, and 415V to suit different regional requirements.
  • Frequency Variants: Operates at both 50Hz and 60Hz, making it versatile for global use.
  • Speed Options: Available in 1500 RPM and 1800 RPM for optimized performance.
  • Cooling System: Advanced water-cooling system ensures efficient heat dissipation for extended operation.
  • Multiple Configurations: Choose from silent type, containerized, super silent, or open type based on your needs.
  • Automatic Start System: Ensures seamless operation during power failures.
  • Heavy-Duty Construction: Weighing 12,000 kg, it is built for long-term durability and stability.

Packaging & Delivery

  • Unit Type: Single unit
  • Packaging Dimensions: 5800mm x 2100mm x 2550mm
  • Gross Weight: 12,000 kg

Why Choose This Diesel Generator?

  1. Reliable Power Supply: Designed for industrial, commercial, and emergency backup power applications.
  2. Fuel Efficiency: Optimized fuel consumption reduces operating costs.
  3. Durable Construction: Built with high-quality materials for long-lasting performance.
  4. Easy Maintenance: Engineered for user-friendly operation and servicing.
  5. Customizable Configurations: Available in multiple soundproofing and housing options to meet specific needs.

Applications

This 1000kW/1250kVA Diesel Generator is ideal for:

  • Industrial Facilities – Ensuring uninterrupted power for manufacturing plants.
  • Data Centers – Providing backup power to prevent downtime.
  • Hospitals & Healthcare Facilities – Supporting critical operations.
  • Construction Sites – Delivering power to off-grid locations.
  • Commercial Buildings & Malls – Ensuring smooth business operations during power outages.

Successful Project

Successful Project

Contact Us

Looking for a reliable power solution? Contact us today to get a quote or learn more about our 1000kW/1250kVA Diesel Generator. Our team is ready to assist you with expert guidance and tailored solutions.

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

Prev:

Next:

Leave a Reply

Laisser un message