400KW Cummins Diesel Generator | XN-400CDG - XN-GEN.COM

Saklaw ng Kapangyarihan/

400KW Cummins Diesel Generator | XN-400CDG

Model: XN-400CDG (Open Frame)

Standby Power: 400KW

Prime Power: 360KW

Voltage Regulation: ≤±1%

Harmonic Distortion: ≤8%

Fuel Consumption: 197 g/kWh

Speed: 1500 RPM

Frequency: 50Hz

Dimensions (L×W×H): 3150×1370×1950 mm

Weight: 4700 kg

  • Product Details
  • Maintenance
  • FAQ

Overview

The 400KW Cummins Diesel Generator is engineered to provide uninterrupted power supply for industrial, commercial, and backup applications. Powered by the Cummins QSNT-G4X diesel engine and paired with a Stamford S4L1D-G41 / HCI444F1 alternator, this generator ensures superior efficiency, durability, and optimal performance.

Key Features

  • Certified Performance: Complies with ISO8528-2005 and GB/T2820-2009 standards.
  • Reliable Power Output: 400KW standby power and 360KW prime power at 50Hz frequency.
  • Advanced Fuel Efficiency: Equipped with a high-pressure common rail fuel system to optimize combustion and reduce fuel consumption.
  • Smart Engine Control: Integrated ECM (Electronic Control Module) for real-time monitoring and diagnostics.
  • Rugged and Durable: Designed to withstand harsh environments with IP23 protection and H-class insulation.
  • Low Emissions & Noise Reduction: Meets global emission standards while operating at reduced noise levels.
  • All-Weather Capability: Functions efficiently at altitudes ≤1000m and temperatures as low as -15°C (can be upgraded for -30°C operation).
  • Extended Warranty & 24/7 Suporta: Backed by 1-year or 1000-hour warranty with nationwide service support.

Technical Specifications

General Specifications

  • Model: XN-400CDG (Open Frame)
  • Standby Power: 400KW
  • Prime Power: 360KW
  • Voltage Regulation: ≤±1%
  • Harmonic Distortion: ≤8%
  • Fuel Consumption: 197 g/kWh
  • Speed: 1500 RPM
  • Frequency: 50Hz
  • Dimensions (L×W×H): 3150×1370×1950 mm
  • Weight: 4700 kg

Engine Specifications

  • Tatak: Mga Cummins
  • Model: QSNT-G4X
  • Max Power: 448KW
  • Number of Cylinders: 6 (Inline)
  • Compression Ratio: 16.3:1
  • Bore & Stroke: 140×152 mm
  • Displacement: 14L
  • Lubrication System: Oil Capacity – 36.7L
  • Cooling System: Closed-loop water cooling
  • Starting System: DC 24V electric start
  • Turbocharging: Water-air intercooling

Alternator Specifications

  • Tatak: Stamford
  • Model: S4L1D-G41 / HCI444F1
  • Rated Power: 450KVA
  • Voltage Output: 400V/230V
  • Excitation System: Brushless, AVR-controlled
  • Power Factor: 0.8 (Lagging)
  • Phase & Configuration: Three-phase, four-wire
  • Protection Level: IP23
  • Insulation Class: H-Class

Environmental Conditions

  • Altitude: ≤1000m
  • Operating Temperature: ≤40°C
  • Humidity: ≤60%
  • Fuel Type: 0# Light Diesel
  • Oil Standard: CF Grade / 15W-40
  • Seismic Resistance: Horizontal – 0.2g, Vertical – 0.1g

Standard Inclusions

  • Complete Diesel Engine System
  • Brushless Stamford Alternator
  • LCD Digital Control Panel
  • High-Quality Radiator & Cooling System
  • Heavy-Duty Steel Base Frame with Anti-Vibration Pads
  • Battery, Silencer, and Engine Oil
  • Automatic Voltage Regulator (AVR)

Optional Features & Mga Pag-upgrade

  • ATS (Automatic Transfer Switch) for seamless power switching
  • Parallel Synchronization Panels (Deep Sea DSE Control Module)
  • Weatherproof & Soundproof Canopy Options
  • Trailer-Mounted Generator Sets for Mobility
  • Remote Monitoring System for Performance Tracking
  • Spare Parts Kit for 500-1000 Hours of Operation

Certifications & Compliance

  • ISO9001 / ISO9002 Certified Manufacturing
  • GB/T 2820-2002 National Standards
  • YD/T 502-2007 Telecom Industry Standard
  • TÜV CertifiedYD/T502-2007
  • Meets ISO3046 & ISO8528 Requirements

Conclusion

The 400KW Cummins Diesel Generator is a premium, fuel-efficient power solution for industries requiring reliable and uninterrupted electricity supply. With advanced control systems, high-performance engineering, and exceptional durability, it is an ideal choice for critical applications.

OPTIONAL FUNCTION

Logistics Packaging

Invest in power you can trust. For more information or to request a quote, please contact our sales team today.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;