2000KW Cummins Diesel Generator | XN-2000CDG - XN-GEN.COM

Saklaw ng Kapangyarihan/

2000KW Cummins Diesel Generator | XN-2000CDG

Tatak: Mga Cummins

Origin: UK (Cummins Inc.)

Model: XN-2000CDG

Max Power Output: 2145KW

Cylinders & Configuration: 16-cylinder, V-type

Compression Ratio: 14.5:1

Bore x Stroke: 159 × 190 mm

  • Product Details
  • Maintenance
  • FAQ

Product Overview

The 2000KW Cummins Diesel Generator is a premium power solution powered by the XN-2000CDG Cummins diesel engine and paired with the Stamford S7L1D-H41/PI734G1 alternator. Operating at 50Hz, it delivers a prime power of 1800KW and a standby power of 2000KW. Designed for high efficiency, superior reliability, and wide adaptability, this generator has earned extensive praise across industries. It also meets strict low-emission standards, making it one of the largest capacity generator sets available for sale in the market.

Product Features

Reliable and Efficient Performance

  • Complies with International Standards: Meets ISO8528-2005 and GB/T2820-2009 regulations for reciprocating internal combustion engine-driven AC generators.
  • Certified Manufacturing: Designed and manufactured under ISO9001/ISO9002 quality certification.
  • Comprehensive Warranty: 1-year or 1000 operating hours full warranty covering the engine, alternator, and control system.
  • 24/7 Nationwide Support: A professional service network ensures prompt technical assistance and after-sales service.

Key Performance Attributes

  • Robust Engine Design: Alloy cast iron cylinder block with replaceable wet cylinder liners for durability.
  • Advanced Air Intake System: Turbocharged system with air-to-water intercooler for optimized performance.
  • Fuel Efficiency: Cummins-patented high-pressure fuel system for complete combustion and reduced fuel consumption.
  • Optimized Lubrication System: Variable flow oil pump for efficient lubrication and reduced wear.
  • Superior Cooling System: Gear-driven centrifugal water pump with rotary water filter to prevent corrosion and impurities.
  • Reliable Electrical System: Equipped with BOSCH starter motor and alternator for efficient charging.
  • Cold Start Capability: Can start in temperatures as low as -7°C without auxiliary equipment.

Environmental Requirements

  • Altitude: ≤1000m
  • Fuel Type: 0# Light Diesel
  • Atmospheric Pressure: ≥89.9 kPa
  • Oil Standard: CF-grade / 15W-40
  • Intake Temperature: ≤40°C
  • Water pH Level: 6.5 8
  • Relative Humidity: ≤60%
  • Mold Resistance: Meets GB/T2423.16/2 level
  • Seismic Resistance: Horizontal acceleration 0.2g, vertical acceleration 0.1g

Generator Set Specifications

  • Type: Open-frame
  • Model: KC2000GF
  • Standby Power: 2000KW
  • Prime Power: 1800KW
  • Dimensions (L×W×H): 6180×2494×3041 mm
  • Weight: 17,800 kg
  • Speed: 1500 RPM
  • Fuel Consumption: 193 g/kWh
  • Frequency: 50Hz
  • Voltage Stability: ±1%
  • Voltage Regulation Time: ≤3 sec
  • Harmonic Distortion (THD): ≤8%
  • Frequency Stability: ±1.5%

Engine Specifications

  • Tatak: Mga Cummins
  • Origin: UK (Cummins Inc.)
  • Model: XN-2000CDG
  • Max Power Output: 2145KW
  • Cylinders & Configuration: 16-cylinder, V-type
  • Compression Ratio: 14.5:1
  • Bore x Stroke: 159 × 190 mm
  • Displacement: 60.2L
  • Oil Pressure: 345 483 kPa
  • Oil Temperature: ≤121°C
  • Oil Capacity: 280L
  • Coolant Capacity: 526L
  • Fuel System: High-pressure common rail
  • Cooling System: Closed water circulation cooling
  • Starting System: DC 24V electric start
  • Governor: ECM electronic control
  • Intake System: Turbocharged, intercooled
  • Steady-state Load Fluctuation: ±0.25%
  • Power Deviation: ≤±5%

Alternator Specifications

  • Tatak: Stamford
  • Manufacturer: Cummins Generator Technologies (China) Co., Ltd.
  • Model: S7L1D-H4 / PI734G
  • Rated Capacity: 2250KVA / 2200KVA
  • Voltage Output: 400V/230V
  • Design: Brushless, single-bearing, rotating magnetic field
  • Excitation System: Self-excited, automatic voltage regulation (AVR)
  • Winding Structure: 2/3 pitch for optimized performance
  • Phases: Three-phase, four-wire
  • Insulation Class: H Class
  • Power Factor: 0.8 lagging
  • Telephone Interference Factor (TIF): <50
  • Harmonic Distortion (THF): <2%
  • Protection Level: IP23
  • EMI Compliance: Meets BS800 and VDE G/N standards
  • Regulatory Compliance: GB755, BS5000 Part 3, VDE0530, NEMA MG1-22, IEC-34, GSA C22-100, AS1359

Standard Configuration

Engine Components:

  • Engine block, fuel filter, air filter, oil filter, alternator, starter motor

Alternator Components:

  • Generator, circuit breaker

Control System:

  • LCD digital display controller, electronic governor

Cooling & Mounting System:

  • Radiator, steel base frame, vibration dampers

Additional Accessories:

  • Silencer, batteries, battery cables, engine oil, anti-vibration pads

Certifications & Standards Compliance

  • Military Standard: GJB 5785-2006
  • National Standard: GB/T 2820-2002
  • Telecommunications Standard: YD/T 502-2007
  • Industry Standard: JB/T 10303-2001
  • Environmental Compliance: Noise & emissions Class A certification
  • TIER Quality Certification: YD/T502-2007

Why Choose the 2000KW Cummins Diesel Generator?

High power output with optimal fuel efficiency

Reliable, durable, and built for heavy-duty operations

Meets global quality and emission standards

Backed by Cumminsextensive service network

Perfect for industrial, commercial, and emergency backup power needs

Video Description

Technical drawings:

Technical drawings:

Successful Project

Successful Project

Logistics Packaging

Get in Touch

For more details, pricing, or inquiries about the 2000KW Cummins Diesel Generator, contact us today! Our experts are ready to help you find the perfect power solution for your needs.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Email Address