120kW Diesel Generator | XN-120GFS - XN-GEN.COM

Saklaw ng Kapangyarihan/

120kW Diesel Generator | XN-120GFS

Model: XN-120GFS

Prime Power Output: 120 kW / 150 kVA

Standby Power Output: 135 kW / 160 kVA

Rated Current: 252A

Voltage Options: 400V / 230V (Three-phase)

Power Factor: 0.8 (Lagging)

Efficiency: 93.7%

Excitation Mode: Brushless Self-excited

Voltage Regulation: ±1%

Protection Grade: IP23

Insulation Class: F

Dimensions (LWH): 2300mm × 850mm × 1300mm

Weight: 1300 kg

  • Product Details
  • Maintenance
  • FAQ

Overview

The XN-120GFS 120kW Diesel Generator is a high-performance power solution designed for industrial and commercial applications. Featuring a robust XN diesel engine, this generator delivers reliable and efficient power output, ensuring continuous operation under demanding conditions. It adheres to international quality standards, including ISO 3046, GB755, BS5000, VDE0530, IEC34-1, CSA22.2, and AS2359.

Technical Specifications

Generator Set

  • Model: XN-120GFS
  • Prime Power Output: 120 kW / 150 kVA
  • Standby Power Output: 135 kW / 160 kVA
  • Rated Current: 252A
  • Voltage Options: 400V / 230V (Three-phase)
  • Power Factor: 0.8 (Lagging)
  • Efficiency: 93.7%
  • Excitation Mode: Brushless Self-excited
  • Voltage Regulation: ±1%
  • Protection Grade: IP23
  • Insulation Class: F
  • Dimensions (L x W x H): 2300mm × 850mm × 1300mm
  • Weight: 1300 kg

Diesel Engine

  • Engine Model: 6HTAA6.5-G32
  • Rated Power: 140 kW / 155 kVA
  • Speed: 1500 RPM
  • Engine Type: 4-Stroke, Inline, Turbocharged & Intercooled
  • Cylinder Bore × Stroke: 105mm × 124mm
  • Number of Cylinders: 6
  • Displacement: 6.5L
  • Compression Ratio: 17.3:1
  • Cooling System: Closed-loop Water Cooling with Radiator & Fan
  • Total Coolant Capacity: 9.6L
  • Operating Water Temperature Range: 82°C – 93°C
  • Maximum Coolant Temperature: 102°C
  • Maximum Oil Temperature: 103°C
  • Total Lubricating Oil Capacity: 17.5L
  • Fuel Consumption at Rated Load: 24.4L/h
  • Governor System: Electronic Speed Regulation (ESR)
  • Exhaust Temperature: 600°C

Alternator

The XN-120GFS is equipped with a high-quality XN synchronous alternator, ensuring stable power generation. It meets international standards for performance and durability.

  • Alternator Brand: XN
  • Rated Power Output: 120 kW / 150 kVA
  • Frequency: 50Hz / 60Hz (Configurable)
  • Voltage Regulation Accuracy: ±1%
  • Excitation System: Brushless, Self-excited
  • Number of Phases: Three-phase

Control System

The generator is integrated with an advanced HGM6110 Automatic Control System, featuring LED indicators for real-time monitoring. This intelligent controller offers:

  • Automatic Start/Stop Function
  • Engine Parameter Monitoring
  • Load Control & Protection
  • Alarm & Fault Diagnosis System
  • Digital Display for Voltage, Current, Frequency, and Running Hours

Battery System

  • Battery Type: Maintenance-free Lead Acid
  • Battery Configuration: 2 × 120AH, 12V

Key Features & Benefits

  • High Reliability & Performance: Built with premium components to ensure stable and efficient operation.
  • Fuel Efficiency: Optimized combustion for reduced fuel consumption.
  • Advanced Protection System: Provides over-voltage, under-voltage, overload, and short-circuit protection.
  • User-friendly Interface: Integrated control panel for simplified operation and real-time status monitoring.
  • Compact & Durable Design: Space-efficient construction with corrosion-resistant materials.
  • Global Compliance: Meets ISO, GB, BS, VDE, IEC, CSA, and other industry standards.

Mga aplikasyon

The 120kW Diesel Generator is ideal for a variety of applications, including:

  • Industrial Facilities
  • Construction Sites
  • Data Centers
  • Hospitals & Healthcare Institutions
  • Commercial Buildings
  • Telecommunications Infrastructure
  • Emergency Backup Power

Why Choose the XN-120GFS Diesel Generator?

  1. Premium Engine & Alternator: High-quality XN diesel engine and synchronous alternator ensure long-lasting performance.
  2. Efficient Power Delivery: Optimized power output with low fuel consumption.
  3. Reliable Operation: Designed for continuous duty with minimal maintenance requirements.
  4. Smart Control System: Advanced monitoring and protection for ease of operation.
  5. Cost-effective Solution: Competitive pricing with low operational costs.

For more details or to request a quote, contact us today!

XN-GEN Diesel Generator MANUFACTURING SHOP

 

SALES AND SERVICE NETWORK

Successful Project

Successful Project

Contact Us

Looking for a reliable and efficient diesel generator? Contact us today for more details, pricing, and availability!

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

Prev:

Next:

Leave a Reply

Email Address