Power Range/

1200KW Cummins Diesel Generator | XN-1200CDG

  • Model: XN-1200CDG
  • Standby Power (KW) : 1200
  • Prime Power (KW): 1120
  • Speed (RPM) : 1500
  • Fuel Consumption (g/kW.h): 205
  • Frequency (Hz): 50
  • Voltage Regulation: ≤±1%
  • Voltage Waveform Distortion : ≤8%
  • Transient Voltage Adjustment: ≤-15%/+20%
  • Steady-State Frequency Regulation: ≤5%
  • Transient Frequency Adjustment: ≤-10%/+12%

  • Product Details
  • Maintenance
  • FAQ

Overview

The 1200KW Cummins Diesel Generator is a top-tier power solution engineered for high reliability and efficiency. Powered by the Cummins KTA50-G8 engine and equipped with a Stamford PI734B1 alternator, this generator delivers a prime power output of 1120KW and a standby power of 1200KW at a frequency of 50Hz. Designed to meet industrial and commercial power needs, it ensures consistent operation with advanced fuel efficiency and an intelligent control system.

Key Features

Powerful Performance: Equipped with a Cummins KTA50-G8 engine, delivering high power and efficiency.

Reliable Alternator: Fitted with a Stamford PI734B1 alternator for stable voltage and frequency output.

Advanced Fuel System: Incorporates PT fuel injection technology for improved combustion and fuel efficiency.

Superior Cooling System: High-capacity gear-driven centrifugal water pump ensures effective cooling.

Robust Construction: Built for durability with low maintenance requirements and a long operational lifespan.

Compliance & Certification: Meets ISO8528-2005, GB/T2820-2009 standards and ISO9001/ISO9002 certification.

Performance Specifications

Specification Details
Model XN-1200CDG
Standby Power (KW) 1200
Prime Power (KW) 1120
Speed (RPM) 1500
Fuel Consumption (g/kW.h) 205
Frequency (Hz) 50
Voltage Regulation ≤±1%
Voltage Waveform Distortion ≤8%
Transient Voltage Adjustment ≤-15%/+20%
Steady-State Frequency Regulation ≤5%
Transient Frequency Adjustment ≤-10%/+12%

Engine Specifications

Specification Details
Brand Cummins
Manufacturer Chongqing Cummins Engine Co., Ltd. (CCEC)
Model KTA50-G8
Standby Power (KW) 1429
Prime Power (KW) 1200
Cylinders & Configuration 16 cylinders, V-type
Compression Ratio 13.9:1
Bore x Stroke (mm) 159 × 159
Displacement (L) 50.3
Oil Pressure (psi) 50-70
Oil Capacity (L) 204
Cooling Water Capacity (L) 477
Starting System DC24V Electric Start
Governing System Electronic
Intake System Turbocharged, Aftercooled

Alternator Specifications

Specification Details
Brand Stamford
Model PI734B
Rated Capacity (KVA) 1400
Voltage (V) 400V/230V
Excitation System Self-excited, Automatic Voltage Regulation
Winding Pitch 2/3
Phase & Connection 3-phase, 4-wire, Y-connection
Insulation Class H-Class
Power Factor COSΦ=0.8 (Lagging)
Total Harmonic Factor (THF) <2%
Telephone Influence Factor (TIF) <50
Protection Level IP23
Compliance Standards GB755, BS5000, VDE0530, NEMA MG1-22, IEC-34, GSA C22-100, AS1359

Environmental & Operational Conditions

Altitude: ≤1000m

Fuel Type: 0# Light Diesel

Atmospheric Pressure: ≥89.9 kPa

Oil Standard: CF Grade / 15W-40

Air Intake Temperature: ≤40°C

Relative Humidity: ≤60%

Vibration Resistance: Horizontal acceleration 0.2g, Vertical acceleration 0.1g

Mold Growth Resistance: Complies with GB/T2423.16/2 level

Standard Accessories

  • Engine Components: Diesel engine, fuel filter, air filter, oil filter, starter motor, alternator
  • Generator Components: Stamford generator, circuit breaker
  • Control System: LCD digital controller, electronic governor
  • Cooling & Structure: Water radiator, steel base frame, vibration isolators
  • Additional Accessories: Silencer, batteries, battery cables, oil, anti-vibration pads

Optional Features & Configurations

Automatic Transfer Switch (ATS) Cabinet

Auto Synchronization Panel (Deep Sea DSE Control Module)

Containerized Generator Set

Mobile Trailer Power Station

Weatherproof Enclosure

Silent Mobile Power Station

Remote Monitoring Interface

FAQ:

1. How to calculate diesel generator fuel consumption?

Fuel consumption is determined by multiplying the generator’s rated power (kW) by the manufacturer’s specific fuel consumption rate (L/kWh). Example: A 50 kW generator with a consumption rate of 0.2 L/kWh will use 10 liters per hour.

2. How to select the right size diesel generator?

Calculate your total power requirements by summing up the power ratings of all connected equipment. Choose a generator with 20-30% extra capacity to accommodate startup surges and ensure smooth operation.

3. How to maintain a diesel generator in high humidity conditions?

  • Keep Dry: Store the generator in a ventilated, dry location.
  • Regular Inspection: Check for moisture, rust, and corrosion.
  • Protect Electrical Parts: Use anti-corrosion sprays on electrical components.
  • Air Filtration: Clean the air filter regularly to prevent moisture buildup.
  • Routine Operation: Run the generator periodically to keep components dry and lubricated.

4. Diesel Generator Maintenance Checklist

  • Daily: Check fuel, oil, and coolant levels.
  • Weekly: Test the battery, run the generator briefly.
  • Monthly: Inspect air and fuel filters.
  • Quarterly: Change oil and filters, inspect belts.
  • Annually: Conduct a full engine tune-up and load test.

5. Silent Diesel Generator Buying Guide

Consider power output, noise levels, fuel efficiency, build quality, and control panel features. Also, evaluate the brand reputation and after-sales support before purchasing.

OPTIONAL FUNCTION

Logistics Packaging

Contact us today to learn more about how the 1200kW Cummins Diesel Generator can provide a robust and efficient power solution tailored to your needs.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply