500KW Cummins Diesel Generator | XN-500CDG - XN-GEN.COM

Power Range/

500KW Cummins Diesel Generator | XN-500CDG

Robust & Reliable Design
Advanced Power Management
Global Standards Compliance
Comprehensive Warranty & Support

  • Product Details
  • Maintenance
  • FAQ

Product Overview

The 500KW Cummins Diesel Generator is engineered to deliver dependable power in both continuous and standby modes. Integrating a robust Cummins KTA19-G8 diesel engine with a high-efficiency Stamford generator, this unit is designed for superior performance, durability, and ease of maintenance. Built to meet international standards, it provides a seamless power solution for a variety of critical applications.

Key Features

  • Robust & Reliable Design:
    Constructed using high-strength materials and advanced processing techniques, the generator boasts a compact, durable structure that minimizes vibration and noise.

  • Advanced Power Management:
    With a backup power rating of 500KW and a continuous operating power of 450KW, it ensures optimal performance in both routine and emergency situations.

  • Global Standards Compliance:
    Designed and tested according to ISO8528-2005 and GB/T2820-2009 standards, with manufacturing quality certified to ISO9001/ISO9002.

  • Comprehensive Warranty & Support:
    Backed by a 1-year or 1000 operating-hour warranty and supported by a nationwide network offering 24/7 technical assistance and after-sales service.

Engine Specifications

  • Model: Cummins KTA19-G8

  • Configuration: 6-cylinder inline, 4-valve per cylinder design

  • Displacement: 18.9 liters

  • Compression Ratio: 13.5:1

  • Fuel System: Electronic control with high-pressure common rail for improved combustion and reduced emissions

  • Cooling & Intake: Closed-loop water cooling with turbocharged and after-cooled air intake for enhanced performance

  • Additional Features:

    • High-strength alloy cast iron block ensuring low vibration and noise

    • Precision-machined components with rigorous quality control

    • Rated backup power of 575KW (engine’s inherent output) ensuring ample power headroom

Generator Specifications

  • Models Available: S5L1D-D4, S5L1S-D4, HCI544D

  • Capacity: 550KVA

  • Voltage: 400V/230V

  • Configuration: Three-phase, four-wire system with brushless, single-bearing design

  • Performance:

    • Fast automatic voltage regulation with transient adjustments ( -15%/+20%)

    • Steady-state voltage stability (≤ ±1%) within 3 seconds

    • Frequency stabilization with rapid adjustment times for continuous performance

  • Design Advantages:

    • Self-excited system with an automatic voltage regulator

    • Optimized winding structure (2/3 pitch) ensuring high efficiency and low distortion

Operating & Environmental Requirements

  • Ambient Conditions:

    • Temperature: ≤ 40°C

    • Relative Humidity: 60%

    • Altitude: 1000 meters

  • Fuel Requirements:

    • Diesel: 0# light diesel

  • Other Conditions:

    • Atmospheric pressure: 89.9 kPa

    • Oil Standards: CF grade (15W-40) with controlled operating temperatures

    • Water quality: pH 6.5 8

Standard Configuration

  • Engine Assembly:

    • Diesel engine with integral filters (fuel, air, and oil)

    • High-performance starter motor and integrated charging system

  • Generator Assembly:

    • Stamford generator paired with an efficient air switch for safety

    • LCD digital control panel paired with an electronic governor for real-time monitoring

  • Cooling & Structural Components:

    • Engine radiator and steel base frame

    • Vibration isolators for enhanced operational stability

  • Accessories Included:

    • Exhaust silencer

    • Battery set with cables

    • Essential operational fluids and anti-vibration mounts

Certifications & Compliance

  • Standards Met:

    • ISO8528-2005 and GB/T2820-2009 for reciprocating engine-driven AC generators

    • Military standard GJB 5785-2006

    • National standards such as GB/T2820-2002, and various international certifications including BS800, VDE, NEMA MG1-22, and IEC-34

  • Environmental & Emission Controls:

    • Compliant with noise, vibration, and exhaust emission certification standards ensuring minimal environmental impact

Optional Configurations

To further tailor your power solution, the following optional configurations are available:

  • ATS Automatic Load Transfer Switch: Seamless switching during power outages

  • Automatic Paralleling Cabinets: For synchronized operation with multiple generator sets

  • Containerized & Mobile Trailer-Mounted Units: Ideal for flexible, on-site power generation

  • Rainproof & Silent Enclosures: Enhancing operational versatility and reducing noise levels

  • Remote Monitoring & Control Interfaces: For efficient, remote system management

Why Choose Cummins?

With a legacy of reliability and innovation, Cummins delivers a power generation system that not only meets but exceeds industry standards. The 500KW Cummins Diesel Generator offers:

  • Proven Durability: Engineered with rigorously tested components for long-term stability.

  • Enhanced Efficiency: Optimized fuel consumption (206 g/kW.h) ensures cost-effective operation.

  • Comprehensive Service: Enjoy peace of mind with professional 24/7 support and a robust warranty.

Invest in a power solution that provides unmatched performance, reliability, and efficiency—choose the 500KW Cummins Diesel Generator for your critical power needs.

OPTIONAL FUNCTION

Logistics Packaging

Invest in power you can trust. For more information or to request a quote, please contact our sales team today.

📧 Email: [ gmail@xn-gen.com]

📞 Phone: [+86 15216161715]

🌐 Website: [xn-gen.com]

Generator Maintenance and Servicing

At XN-GEN, we offer long-term maintenance agreements to provide professional, high-quality, and hassle-free service for our customers. Our maintenance services ensure the optimal performance and longevity of your generator set. Below is a general guideline for maintenance procedures (please note that specific actions may vary based on the model and operational status of each generator set).

Routine Maintenance

Regular inspections and upkeep are crucial to ensuring the reliability of your generator. The following checks should be performed regularly:

  1. Inspect all rotating components and tighten any loose bolts.
  2. Check the oil level in the crankcase and add oil if necessary.
  3. Monitor fuel levels in the tank.
  4. Inspect the coolant level in the radiator.
  5. Examine fuel and water pipelines for any leaks or loose connections.
  6. Ensure the intake and exhaust systems, along with cylinder gaskets, are properly sealed.
  7. Clean any oil stains or dust accumulation on the generator to maintain a tidy machine room.

Maintenance Plan for Standby Generators

(Recommended for backup generators used in residential communities, commercial buildings, hospitals, government facilities, tourist attractions, factories, and other locations where power outages are rare.)

Professional Maintenance (Every Six Months or Annually)

In addition to routine maintenance, a comprehensive service should be performed every six months or once a year:

  1. Conduct a thorough inspection of the fuel, electrical, cooling, and lubrication systems to ensure proper functionality.
  2. Perform a no-load test run for 5-10 minutes to lubricate the system. Assess the generator's performance using auditory, visual, and olfactory checks.
  3. Replace consumable filters, including air, diesel, oil, water, and fuel-water separators.
  4. Drain and replace coolant, ensuring proper radiator function.
  5. Check and replenish the battery electrolyte or distilled water as needed.
  6. After completing the maintenance, conduct a final inspection and clean the generator set.
  7. Perform another 5-10 minute no-load test, record performance parameters, and provide optimization recommendations before customer acceptance.

Maintenance Plan for Continuous Operation Generators

(Recommended for generators in construction sites, frequently power-outage-prone factories, areas with insufficient transformer capacity, project testing sites, or locations without access to the main grid.)

Level 1 Maintenance (Every 50-80 Hours)

This includes all routine maintenance tasks plus:

  1. Clean the air filter and replace it if necessary.
  2. Replace the diesel filter, air filter, and water filter.
  3. Inspect the tension of the drive belt and adjust if needed.
  4. Lubricate all grease fittings and moving components.
  5. Replace coolant to maintain effective cooling performance.

Level 2 Maintenance (Every 250-300 Hours)

Includes Level 1 maintenance tasks, with additional checks:

  1. Clean and inspect pistons, piston pins, cylinder liners, piston rings, and connecting rod bearings for wear.
  2. Examine the main bearing for any signs of looseness or abnormal wear.
  3. Remove scale and sediment from the cooling system to ensure proper heat dissipation.
  4. Clear carbon deposits from the combustion chamber and intake/exhaust passages.
  5. Inspect and adjust valve clearances, valve seats, push rods, and rocker arms.
  6. Clean turbocharger rotors and check bearings and impellers for wear, replacing if necessary.
  7. Tighten or replace any loosened or damaged bolts in the generator-diesel engine coupling.

Level 3 Maintenance (Every 500-1000 Hours)

Includes Level 1 and Level 2 maintenance tasks, along with additional services:

  1. Check and adjust the fuel injection timing.
  2. Clean the fuel tank to remove contaminants.
  3. Clean the oil sump to prevent sludge buildup.
  4. Inspect and test the fuel injectors for optimal atomization.

By following this structured maintenance plan, generator owners can ensure consistent performance, increased lifespan, and reduced risk of unexpected failures. Our expert team at XN-GEN is dedicated to delivering superior service to keep your power supply reliable at all times.

For more information or to schedule maintenance, contact us today!

1. Are you a factory or a trading company?

We are a factory specializing in the production of various types of generator sets. Our manufacturing facility ensures high-quality production and strict quality control.

2. What are your main markets?

Our products are widely exported to South America, the Middle East, Southeast Asia, and Africa, catering to diverse power needs across different industries.

3. How do you ensure product quality?

We implement strict quality control measures at every stage of production. Before delivery, all generator sets undergo load testing inside a shipping container to ensure optimal performance and reliability.

4. What is your warranty policy?

Our products come with an industry-standard warranty of one year or 1,000 operating hours (whichever comes first). We also provide technical support and spare parts services.

5. Can we customize the generator with our logo or design?

Yes! We offer custom branding for authorized logos and designs, allowing you to personalize the generator’s appearance according to your business needs.

6. What is your delivery time?

Our standard production and delivery time is within 15 working days, depending on order quantity and customization requirements.

7. How can I become your distributor?

We welcome partnerships with companies that have strong marketing resources and after-sales service capabilities. If you meet these criteria and are interested in collaborating, feel free to contact us for further discussions.

8. Do you provide after-sales support?

Yes! We offer technical assistance, spare parts supply, and remote troubleshooting to ensure seamless operation of our generator sets.

9: What is the payment terms you can accept?

  • A: T/T, 30% deposit, 70% will be paid before delivery;
  • or T/, 30% deposit, 70% L/C at sight;
  • or 100% L/C at sight;

Prev:

Next:

Leave a Reply

Leave a message